Да ли су вам стандарди потребни у вашем послу?
Да
Не
Понекад
Не знам
Укупан број гласова: 7104

Пријавите се!
 

SRPS EN 1090-5:2017

Статус: Објављен
Језик: Engleski
Бр. страна: 61
Датум: 31.08.2017.
Службени гласник:
Број решења: 2910/46-51-02/2017
Издање: 1 ED
Веза са међународним стандардима
Ovaj standard je identičan sa:
EN 1090-5:2017   CEN/TC 135
Цена: 4106 RSD

За читање онлајн

Одштампај

Наслов на српском језику

Izvođenje čeličnih i aluminijumskih konstrukcija – Deo 5: Tehnički zahtevi za hladnooblikovane aluminijumske konstrukcijske elemente i hladnooblikovane konstrukcije za krovove, tavanice, međuspratne konstrukcije i zidove

Наслов на енглеском језику

Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications

Апстракт на српском језику

Ovim standardom se utvrđuju zahtevi za izvođenje, odnosno proizvodnju i ugradnju hladnooblikovanih aluminijumskih konstrukcijskih komonenata izrađenih od profilisanih limova za primenu kod krovova, tavanica, međuspratnih konstrukcija i zidovа, pretežno opterećenih u uslovima statičkog ili seizmičkog opterećenja, kao i za njihovu dokumentaaciju. Obuhvata proizvode konstrukcijske klase I i II prema EN 1999-1-4 koje se koriste u konstrukcijama.

Апстракт на енглеском језику

This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures. Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part. Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas. This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements. A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply. Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or - suspended ceilings for interior fitting.

Комисија за стандарде


ICS



Директиве

Нема информација.

Национални пропис

Нема информација.

Национална активност

Нема информација.

Дескриптори

konstrukcije, aluminijum, izvođenje (operacija građenja), zavarivanje, zavareni spojevi, spojna sredstva, obrada površine, zaštita od korozije, kontrolisanje, kontrola kvaliteta, tolerancije (merenje), metalni preseci, zgrade


Извор

 Ознака стандарда
Језик
Статус
Датум
Бр. страна
Цена
 
Купи
Engleski
Повучен 
17.12.2018 . 
209 стр.
6035 RSD 
PDF
Izvođenje čeličnih i aluminijumskih konstrukcija — Deo 2: Tehnički zahtevi za čelične konstrukcije